Naming rule: load cell LWA (a) -b-c-d-e-f-g-h-i
|
Product Type a |
Model b |
Elastomer Class c |
Capacity (kg) d |
Certification/Area e |
Temperature f |
Load Cell Accuracy g |
Load Cell Cable Length h |
Backup i |
|
LW-Load cell A-Analog Load cell |
WBTSC WBTSB WBTSH |
(Blank): Alloy steel
|
50,100, 200, 300,500, 1000, 2000, 3000,5000 |
N: Standard X: Explosion-proof |
S: Normal temperature |
C3 |
5m |
A: Standard, output sensitivity 2.0 mV/V F: Customization |
|
Specifications |
|||||
|
Model |
|
WBTSC |
WBTSB |
WBTSH |
|
|
Rated capacity |
|
50,100, 200, 300,500,1000 |
2000,3000,5000 |
0.2,0.3,0.5,1, 2, 3,5t |
|
|
Sensitivity |
mV/V |
2±0.002 |
|||
|
Accuracy class |
|
C3 |
|||
|
Repeatability error |
% R.C. |
≤0.01 |
|||
|
Lag |
% R.C. |
≤0.02 |
|||
|
Non-linearity |
% R.C. |
≤0.018 |
|||
|
Creep (30 minutes) |
% R.C. |
≤0.0167 |
|||
|
Zero output |
% R.C. |
≤1 |
|||
|
Temperature compensation range |
°C |
-10~+40 |
|||
|
Opeclassification temperature range |
°C |
-40~+65 |
|||
|
Temperature coefficient of sensitivity |
% R.C./°C |
≤0.0009 |
|||
|
Zero temperature coefficient |
% R.C./°C |
≤0.002 |
|||
|
Input impedance |
Ω |
385±10 |
|||
|
Output impedance |
Ω |
350±1 |
|||
|
Insulation resistance |
MΩ |
≥5000 (100V DC) |
|||
|
Recommended excitation voltage |
V (DC/AC) |
5-15 |
|||
|
Maximum excitation voltage |
V (DC/AC) |
20 |
|||
|
Safety overload |
% R.C. |
150 |
|||
|
Extreme overload |
% R.C. |
300 |
|||
|
IP Class |
|
IP65 |
IP67 |
||
|
Cable length |
m |
5 |
|||
Overall dimension (mm)
|
TSC Series mounting dimensions
|
TSB Seriess mounting dimensions
|