Product Description
Parameters:
Channel setting | 16 channels, Thousands of particle sizes can be customized and the accuracy is 0.1 μ m |
Test range | 1-500 μ m (Segment sensor require) |
Count range | 0 ~ 99999 particles |
Sampling volume | 0.2ml-1000ml |
Accuracy | <±0.5%(0.2ml~1000ml) |
Syring size | 10ml、25ml |
Flow rate | 2~100ml/min, setting by self |
Counting accuracy | <setting value±5% |
Channel resolution | >95% |
Relative standard deviation | RSD<1.5%(standard particle≥1000 /ml) |
Maximum Concentration | 0~18000 /ml |
Mixing speed: | 0 ~ 2000 R / min, adjustable in spinning type |
Work temperature | 10~40℃ |
Power | AC220Ⅴ±10%;50Hz;<80W |
Data output | RS232 |
Dimension | 390*350*460(mm) |
Weight | 20KG |
Software | With audit trail ,can operate in PC |
Operation system | Windows 7, windows 10 |
Futures:
- NBC-36s particle detector can fully meet the design scheme of Chinese Pharmacopoeia (2020Edition) and the requirements of Pharmacopoeia of the United States, for the detection of insoluble particles in small volume injections. It can also be used for the detection of particles in large infusion and infusion equipment, the filtration effect of infusion terminal filter and other fields (such as petroleum, chemical industry, dye, food, etc.) of liquid particles testing.
- High performance imported laser light source and compensation circuit are adopted to ensure the test accuracy of colorless and colored samples, and the samples without electrolyte can be directly detected
- The imported high-pressure injection pump sampling system is adopted, which can be set according to the sample volume of the tested sample varieties, with high injection accuracy, meeting the detection requirements of high viscosity test articles, and not affected by geographical location and other factors, meeting the use requirements of different altitude areas.
- The injection slit and pipeline are made of imported 316L and PTFE materials, which can directly detect organic solvents, oil matrix and other special solutions.
- Different high-pressure injection systems can be replaced according to the demand of injection quantity.
- It is equipped with pharmacopoeia standard infusion test, and the test times can be set arbitrarily.
- There is a special test program for small volume injection (small injection), which can be injected according to the specifications of small injection, and automatically converted into the size and quantity of container particles after the test, which meets the requirements of Chinese Pharmacopoeia and international general requirements.
- It can detect the content of particles in anesthesia bag
- Detection of filtration rate of precision filter
- Detection of particulate pollution in GB8368-2005
- Detection of particulate pollution in GB8368-2018
- Detection of particle content of drug packaging materials
- Detection of particle content of drug packaging materials
- Full channel test (better than the calibration requirements for instruments in Pharmacopoeia)
- The screw type glass agitator is adopted, with uniform speed adjustable, and the mixing speed can be controlled at any time to ensure the uniformity of particles in the container. Improve data accuracy
- Color touch large screen operation: Chinese input, easy and fast operation, powerful function. Multi channel test data can be displayed at the same time.
Sample name storage function: the set sample name is automatically stored, which is convenient and quick to operate. It has automatic data processing and multiple printing modes to meet different printing needs. - It can be connected to the computer and has the function of data automatic transmission computer; it can be connected to the laboratory operation for management, and the special data analysis software is used for data storage and statistics
- Three level authority management
- 32 users operator management
- It has data view function, and can access historical data and operation behavior at any time
AI Product Description
*The following content is generated by AI and is for reference only.
The device described is a liquid-borne particle counter, an essential instrument used across pharmaceuticals, biotechnology, food and beverage, and semiconductor manufacturing industries to ensure fluid purity. Its primary function involves detecting and counting microscopic solid particles suspended within liquids, such as water for injection (WFI), purified water, solvents, or process fluids. By measuring the size and quantity of these contaminants, typically ranging from 0.1 micrometers to several hundred micrometers, the equipment provides critical data for quality control and regulatory compliance with standards like USP <788> or ISO 11171.
These instruments operate on the principle of light obscuration or laser scattering, where a sample flows through a sensing zone illuminated by a high-intensity light source. As particles interrupt the light beam, they generate electrical pulses proportional to their size, allowing for precise classification and quantification. This capability is vital for identifying potential risks of clogging, product contamination, or equipment failure before they impact production lines or patient safety.
Key operational precautions must be observed to maintain accuracy and extend instrument lifespan. First, samples must be free of air bubbles, which can cause false readings; therefore, proper degassing techniques are mandatory prior to analysis. Second, the flow cell and optical sensors require rigorous cleaning protocols to prevent cross-contamination between different batches or fluid types. Operators should strictly adhere to recommended flow rates to avoid damaging delicate internal components. Furthermore, regular calibration using certified reference standards is crucial to ensure measurement traceability and reliability. Environmental factors such as temperature fluctuations and vibration should also be minimized during operation. Finally, personnel must follow strict hygiene procedures when handling sensitive optical surfaces to avoid introducing new particulates. By integrating these devices into routine monitoring programs, organizations can effectively safeguard product integrity, optimize manufacturing processes, and meet stringent global regulatory requirements for clean fluid systems.